VisiLogic
V8.00 Features OS V 3.0.0 |
|
Note that some of the information below refers to Vision Divisions. These are: Standard Vision:
V120, V230, V260, V280, V290, and V530 Enhanced Vision:
V570, V290-C, 350, and V130 |
|
New Software Utilities |
The release of V8.00 includes new software
available from the Utilities section of this Downloads page. SD
Suite Software ·
The SD Explorer, enabling you to remotely access, download, upload
SD data without ever removing it from the PLC. ·
The SD Manager, offering a variety of tools to convert, view, edit, and manipulate SD data. Remote
Operator ·
This new Standalone software utility enables you to use your PC to view
remote HMI screens and click on-screen objects of a large number of remote
Unitronics Vision, M90/91, and Jazz controllers. |
|
|
SD Card |
SD Password |
Guards SD data. |
|
Folder Report |
Reports the number of files currently in an SD folder, and the number of files can still be created in that folder. |
|
|
SD to/from Data Table |
Use these to read and write data between Data Tables and SD card. |
|
|
SD Trend |
Record an entire or partial trend to a .utr file in the SD card Trends folder. Display Trend directly from a .utr file via HMI element Trend from SD. |
|
|
SD Excel |
Pull numeric data or text strings from the PLC and use delimiters to structure a line; then create an Excel file on an SD Card. Supports .csv & .txt lines |
|
|
Data Blocks |
Create, and then read/write PLC data to storage areas in the SdBLocks folder on a SD card. SD Data Blocks may reach a total of 4G. |
|
|
Data Files |
Use Windows Explorer to store any type of file onto an SD card, such as .html or .jpg. Via Ladder, read and write these files in 'chunks' of 512 bytes. You can also use these functions to pull data from the PLC and create files on the SD card. |
|
|
SD Card |
SD Browser: Trend from SD: a new option on the Display Trend variable |
|
|
|
Now supports SDHD cards. |
|
|
String Library (Enhanced) |
·
String Libraries have been increased to 16, making it easy to create a
single application that can serve end-users in 16 languages. ·
Strings can be imported/exported from/to Excel. ·
Both features are in String Library> File ·
Find Unreferenced Strings is a new tool on the String Library toolbar. |
|
Complex Web Server (Enhanced, TCP/IP) |
Build your web pages using an HTML editor. Download them to an SD card in an Enhanced Vision running Enhanced PLC Webserver.vlp. available from: http://www.unitronics.com/data/uploads/communication/WebServer.zip The Vision can host pages with a variety of colors, fonts, links to other sites, and scripts. The controller must comprise a TCP/IP port, and must be connected to an Ethernet network. |
|
Vision570 + onboard
I/Os Support |
Vision V570-57-T34 OPLC—a new V570 model that offers on-board I/Os (not yet released to market) |
|
XL I/O Expansion Module support |
XL I/O modules comprise enhanced I/O configurations and detachable I/O connectors. In addition, Some module comprises a built-in adapter for communicating with the PLC and providing power to the other expansion modules in the system |
|
SAE J1939 CANbus Protocol, CANbus modes |
If your Vision comprises a CANbus port, you can use: ·
SAE J1939: Configure, then
Send/Receive PGNs. Located on · CANopen + CANLayer2: now available as simultaneous modes as option in COM Init · New Ladder Element: Map Register bytes can aid in managing CANOpen messages, reordering, expanding, and distributing. |
|
New Ethernet features |
New functions available on the COM TCP/IP menu are: ·
· Email>SMTP Mail Authentication · SNMP(slave) |
|
Built-in Web Server (Enhanced,TCP/IP) |
· Advanced Options enable user logo, and logo via external link. · New option ‘Editable’ enable user to send value to PLC via web interface |
|
DF1 Slave |
Enables Vision to be slave to the DF1 AB protocol, COM >DF1 |
|
Frequency Measurement |
New Ladder function on the Immediate menu enables you measure High-speed Input frequency with resolution and accuracy of 0.01 Hz.. |
|
Data Tables |
New Ladder functions on the Data Tables menu: · Copy a Data Table Row to Operand Vector · Copy a Vector of Operands to a Data Table Row |
|
Alarms |
Now supported by V130 |
|
OEM: Image
Customization |
You can replace the following Unitronics proprietary system images in your application, by placing an image on the display, right-clicking it and selecting Default OS Images: · Information Mode: replace the Unitronics logo · System Busy: replace the VisiLogic image · Start-up Splash screen: replace the DOS-style screen |
|
New Ladder Tools |
· Advanced Find and Replace: Edit> Replace Operand now supports Replace in HMI Displays · Address Vector: when addressing an Operand, you can assign a vector of operands a name, and automatically assign consecutive numbers. |
|
On-line Test Mode |
Go to HMI Screen: when you are in Test mode, you can jump the VisiLogic application to the display that you see on the controller’s HMI screen by clicking the HMI icon on the Test toolbar. |
|
HMI Variable Features
(Color Division) |
· Select Touch keyboard type: Select this when creating a Keypad Entry Variable · Numeric Variable-Range: You can now change colors according to range of values. · Display Background –Image: Right-click a display, and select a background image. · Graphical button: You can now select an image when creating a button. |
|
|
This
format can now be viewed when running |
|
HMI Improvements |
Text: when you create/edit a text box, there are new Alignment options; in addition, older options work in accordance with expected standards. |
|
VisiLogic
V7.0.1 Features OS V 2.001.00 |
|
Note that some of the information below refers to Vision Divisions. These are: Standard Vision:
V120, V230, V260, V280, V290, and V530 Enhanced Vision:
V570, V290-C, 350, and V130 |
|
X-Operands |
These
are now supported by a broader range of functions. |
|
Find
& Replace |
Now supports X-operands |
|
VisiLogic
V7.0.0 Features OS V 2.001.00 |
|
Note that some of the information below refers to Vision Divisions. These are: Standard Vision:
V120, V230, V260, V280, V290, and V530 Enhanced Vision:
V570, V290-C, 350, and V130 |
|
Vision350
Support |
Vision350 OPLCs belong to the Color Vision Series, comprising a 3.5” TFT touchscreen that can show over 1000 displays; with a 3.5MB capacity for images & fonts. 7 models are currently available, each with a different on-board I/O configuration which may include PT100/TC and analog outputs. Via local and remote I/O Expansion Modules, V350 can support up to 512 I/Os. Additional features include: Built-in operating panel containing an touchscreen LCD and a keypad ♦ 1 built-in serial port: RS232/RS485 ♦ Optional: the user may order and install additional ports: RS232/RS485/Ethernet and CANbus ♦ SD card support |
|
Remote I/O (all models supporting CANbus) |
The EX-RC1 remote I/O module adapter enables you to distribute I/O Expansion Modules throughout your system. The adapter is connected to a master PLC by UniCAN, Unitronics’ proprietary CANbus protocol, and functions as a slave device within that network. Each adapter may be connected to up to 8 I/O expansion modules. Up to 512 I/Os may be connected to a single controller, depending on the models you select. |
|
SD
Cards: Removable Memory Storage (Enhanced only) |
Enhanced Vision controllers now support SD cards. The V570 supports standard SD cards; V130 and V350 support micro SD cards. You can: · Enable a VisiLogic application to store complete Data Tables, and to log Data Table rows to an SD card · Import data on a SD card into Data Tables via VisiLogic · Apply a password to prevent programs being uploaded from the controller to an SD card · Store Alarms History on SD ·
Use Information Mode to: ·
Use |
|
Send e-mail (all models
supporting TCP/IP) |
This function enables a controller to send an email in response to Ladder conditions. In order to send email, the controller must comprise a TCP/IP port, and must be connected to an Ethernet network with access to an SMTP or ESMTP server. |
|
Web
Server (Enhanced only, supporting TCP/IP) |
Enhanced Vision controllers can act as servers and host web pages that can display operand values including timers and counters, and Alarm warnings. The controller must comprise a TCP/IP port, and must be connected to an Ethernet network. |
|
Stepper via High-speed Output (V570 only) |
Snap-in I/O modules offer high-speed outputs. If you are using a V570 with any model Snap-in I/O module, VisiLogic 7.00 or higher and the relevant OS, you can use these outputs to control stepper motors. Note that any acceleration and deceleration that is needed to arrive at Target safely and accurately must be implemented via Ladder. |
|
Trends
HMI Variable: New Feature (Enhanced only) |
·
V130 support ·
Y-axis value ·
Remote Access |
|
Information Mode: Additions for
V130 |
· View CANbus settings · See connected I/O Expansion Modules · View the PLC Name · Monitor Ethernet communications as they flow through the port |
|
1.25 mS
Interrupt Routine |
The 1.25 mS is called by naming a subroutine _Interrupt 1.25 mS. |
|
New Stop Mode Subroutine (All models) |
If you include a subroutine
named:_RUN_TO_STOP_ |
|
New Boot Mode Features
(Enhanced only) |
The OS version released with VisiLogic 7.00 also adds new Boot Mode features ·
OS Download · Boot Info Mode: This gives you the ability to check software and certain hardware versions, view and edit Unit ID as well as certain CANbus, serial, and Ethernet settings. You enter this mode just like standard Information mode: when you are in Boot mode, touch ( or in the case of the V130 hold down the <I> key) for 7 seconds. |
|
Import/Export Displays |
You can export displays and save them as .vld files, then import them into other projects. |
|
HMI
Variable Features (Enhanced/Color Division) |
· Password: you can now display text in the password variable · Numeric Variables: can now display MF values · Binary Text, List of Texts: supports background color, text from String Library ·
List of Texts, · List of Images: Select groups of images; when in the Select Image box, by holding down the Ctrl button and clicking images ·
Project>Properties>Colors:
you can select default colors for: |
|
UniDownloader |
Additional details regarding this new feature will soon be available. The UniDownloader package enables you to build a complete, compressed project and send it anywhere to be installed in a PLC using a standalone downloader. Your end user will be able to download the application, but will not be able to view or modify it. The tool can download applications and OS. The package comprises the UniDownload Designer, located on the Tools menu, and the UniDownloader, available as a separate download from www.unitronics.com. |
|
UniEDS |
Use the UniEDS to open CANopen EDS files. The utility is located on the Tools menu. |
|
Additional Features (All
models) |
· Struct: supports MI to Inputs · UDP and TCP RAW functions are located on the COM>TCP/IP>UDP menu. Use them to send a vector of raw data to a remote Vision, broadcast the data to the entire network, or receive a stream of data and write it to a vector of registers · FB Protocol: now supports STX in checksum calculations · New Function: Replace String · Keystroke Ctrl + Z now undoes the last action |
|
Additional Features (Enhanced
only) |
· OS download via Ethernet · Alarms: Supported in Remote Access ·
Virtual Keypads: Enhanced Touchscreen Models · Relevant X Operand types are now supported in NUM to ASCII functions, and in the Events FB · Color models only: Trend (Legacy) FB- you can write a value into SI 48 to change the color of the Trend as it is being drawn |
Issue: CANopen
compatibility break
|
The CANopen System Operand addressing scheme changed as of VisiLogic version 7.00, OS OS 2.00 (Standard Division) OS 5.02 (Enhanced Division). You can choose to continue editing older applications using previous VisiLogic versions contained in the VisiLogic Verison Swapper. Note that in this case the controller must use an older OS. |
|
VisiLogic V6.0.1 Features OS V1.002 (B7) |
|
|
Known Issues:
XB- Using a Negative Transition
Contact returns a runtime error. Please do not use XB Negative Transition
Contacts in your applications. V570: The Virtual Keypad does not offer
separate plus (+) and minus (-) signs. This will be fixed in an upcoming
version, with the plus and minus sign replacing the exponential signs ‘2
‘ and ‘3’. Please do not use these
exponential signs in your applications. |
|
|
The bugs listed below are fixed in V6.01 |
|
|
V130: OS Update from the Web |
This is
supported in this version |
|
Polish Interface |
Polish has
been added to the VisiLogic interface languages |
|
Processing Memory Floats |
The new OS
processes floats more rapidly. Note that the OS may be downloaded using the
VisiLogic Help menu Help>Update From the Web, and installed in the
controller. |
|
VisiLogic V6.0.0 Features (Requires OS update) |
|
|
Note that some of the information
below refers to Vision Divisions. These are:
|
|
|
Supports micro-OPLC series: Vision130™ |
Vision130™ micro-OPLCs belong to the Enhanced Division. V130 is a
palm-sized, rugged programmable logic controller that comprises: On-board I/O
configuration ♦ Built-in operating panel containing an LCD and a keypad
♦ 1 built-in serial port: RS232/RS485 ♦ Optional: the user may
order and install additional ports: RS232/RS485/Ethernet and CANbus |
|
New Ladder functions (Enhanced) |
·
Set String Library ·
Library String to ASCII |
|
New Ladder functions (all controllers |
·
Store: RESET
Numeric Value ·
Strings: Step
In Range, String to ASCII, Remove String From String, Insert String to
String, Left Part of String, Right Part of String, Middle Part of String,
Find String within String, and Timer to ASCII ·
COM: Set
PLC Network ID ·
Data Tables: Set
column value in Data Tables ·
HMI: Refresh
HMI Display ·
Logic: Toggle
Register Bit ·
Copy Vector: Timers
added to Operand Type |
|
Alarms (V570 only) |
Alarms are
linked to a built-in set of Displays. Your application determines how and
when an Alarms Display is shown. |
|
String Library (Enhanced) |
Organize text
into different String Libraries—for example, separate libraries for Spanish,
English and Italian—pull strings into HMI objects, and then switch libraries
to change the display language. |
|
X Operands (Enhanced) |
X Operands are
processed within the CPU's RAM memory. Use them in subroutines where scan
time is critical, for example during Interrupt Routines. Note that since they
are not backed up by battery, they are always 0 at power up. |
|
More Operands (V570) |
Operands
increased to: MB – 8192, MI – 4095, ML – 512, DW – 256, MF – 64, Timers - 384
Counters - 32 |
|
Color Vision Features |
·
New Graph object: Thermometer ·
ASCII entry via touch ·
COM 3 now supported for serial communications ·
Draw Line (Cartesian, polar coordinates; vary width,
length, and color.) ·
Trends: Curve name may be taken from String Library, Min.
and Max Y axis values may be indirectly set from operand, and decimal values
may be used Now supports
the HMI objects Round Rectangle and Ellipse |
|
Help- in
Spanish - Ayuda en Español |
At installation, VisiLogic
installs both English and Spanish Help files. If the user selects the Spanish
interface (View>Language>Spanish) VisiLogic will refer to the Spanish
files. Note that the English Help files, which are the most recently updated,
can always be accessed via the Windows Start menu (typically Start
>Unitronics> VisiLogic>Help |
|
VisiLogic V5.2.3 Features (Relevant for V570, V290-C. Requires OS update) |
|
|
Transitional contacts |
Number of
permitted Rise/Fall elements increased to 1024 |
Trends
|
Now
supports decimal point in Y-axis value |
|
VisiLogic V5.2.2 Features |
|
|
Telestar Modem |
Now
supported by VisiLogic. V570
Known Issue: if Telestar modem uses a SIM card that requires a PIN, the modem
cannot dial out. |
Wavecom GPRS Modem
|
Improved
support for V120/230/260/280/290 monochrome. |
|
VisiLogic V5.2.1 Features |
|
|
Calls and Jumps |
Number of
Call Subroutine functions and Jump to label is now unlimited in ALL models
(previously, was limited to 297). |
|
Parameter
“Silence Duration” -The value is now displayed in 32usec units in SI 137 (COM
1)138 (COM2), 139 (COM3). |